cABLES

The usage areas and technical specifications of high-current cables most commonly used in installations...

NYY-(YVV) CABLES

Usage Areas: These cables, used as network lighting and power distribution cables, are suitable for indoor, outdoor, underground, and cable channel applications where there are no excessive mechanical stresses.

Cable Structure:

  • In single-core cables, single-wire conductors are used up to 1.5-10 mm², and multi-wire conductors are used from 10 mm² to 300 mm².
  • The conductors are insulated with an insulating sheath and covered with an outer sheath.
  • In multi-core cables, single-wire conductors are used up to 10 mm², and multi-wire conductors are used for larger cross-sections. The twisted conductors are covered with a common sheath and a black outer sheath.

Maximum Conductor Temperature: 70°C

Rated Voltage: 0.6/1kV

NHXMH CABLES (Halogen Free)

Usage Areas: These cables are used in large hotels, hospitals, shopping centers, power plants, data processing centers, and rail systems where there is a high risk of fire and the presence of many people and valuable equipment. These cables do not transmit flames during a fire, do not create dense smoke layers, and do not create a corrosive environment, thus ensuring the safety of life and property.

Cable Structure:

  • Conductor: Single or stranded copper conductor
  • Insulation: XLPE compound
  • Outer Sheath: LSFOH thermoset
  • Filling: LSFOH thermoset

Maximum Conductor Temperature: 70°C

Rated Voltage: 300V/500V

N2XH CABLES (Halogen Free)

Usage Areas: These cables are used in business centers, shopping centers, hotels, schools, tunnels, and other places with a high risk of fire where many people are present.

Cable Structure:

  • Conductor: Solid or stranded copper conductor
  • Insulation: XLPE insulation
  • Filling: Special LSFOH
  • Sheath: Special LSFOH

Standards: VDE 276-604

Maximum Conductor Temperature: 90°C

Rated Voltage: 0.6/1 KV

NHMH CABLES (Halogen Free)

Usage Areas: These cables are used in business centers, shopping centers, hotels, schools, tunnels, and other places with a high risk of fire where many people are present.

Cable Structure:

  • Conductor: Solid or stranded copper conductor
  • Insulation: Special LSFOH insulation
  • Filling: Special LSFOH
  • Sheath: Special LSFOH

Standards: VDE 0250-215

Maximum Conductor Temperature: 70°C

Rated Voltage: 300/500 V

N2XY CABLES

Usage Areas: These cables, used as network, lighting, and power cables, are suitable for indoor, outdoor, underground, and cable channel applications where there are no excessive mechanical stresses.

Cable Structure:

  • Conductor: Copper conductor
  • Insulation: XLPE (cross-linked PE)
  • Filling: PVC
  • Outer Sheath: PVC

Standards: TS IEC 60502, IEC 502, VDE 0271, BS 6346

Maximum Conductor Temperature: 90°C

Maximum Short Circuit Temperature: 250°C

Rated Voltage: 0.6/1 KV

NVV (NYM) CABLES

Usage Areas: These cables are used in humid places where there are no mechanical stresses, in all kinds of residential and business buildings, both under and on plaster.

Cable Structure:

  • Conductor: Copper conductor
  • Insulation: PVC
  • Filling: PVC
  • Outer Sheath: PVC

Standards: TS 9759 HD 21.4 S2, VDE 0250-204, BS 6004

Maximum Conductor Temperature: 70°C

Rated Voltage: 300/500 V

H07V-U (NYA) CABLES

Usage Areas: These cables are used in closed or dry places, distribution panels, fixed installations, and installations inside pipes.

Cable Structure:

  • Conductor: Copper conductor
  • Insulation: PVC

Standards: TS 9758 HD 21.3 S3, VDE 0281-3, BS 6004

Maximum Conductor Temperature: 70°C

Rated Voltage: 450/750 V

H05VV-F (TTR) CABLES

Usage Areas: These cables are used in household appliances in dry and humid places with low mechanical stresses.

Cable Structure:

  • Conductor: Fine stranded copper conductor
  • Insulation: PVC
  • Filling: PVC
  • Outer Sheath: PVC

Standards: TS 9760 HD 21.5 S3, VDE 0281-5, BS 6500

Maximum Conductor Temperature: 70°C

Rated Voltage: 300/500 V